Skip to content

SmartSight Nova in Warsaw and Krakow: Why Centration Precision is Crucial for Your Vision?

SmartSight Nova represents the technological pinnacle of flapless vision correction (lenticule extraction) performed with the Schwind Atos femtosecond laser. The key to this method’s success is an integrated process: from diagnosis with the MS-39 tomograph (2nd generation), through automatic iris recognition (Iris Registration), to the unique Centrax software. This software allows for precise centration of the procedure relative to the patient’s visual axis after the eye has been immobilized (vacuum application). This approach prioritizes mathematical accuracy over laser speed alone, resulting in better night vision quality and minimized side effects.

In refractive surgery, precision is not a matter of chance, but the result of excellent device integration. SmartSight Nova at Swisslaser is not just about laser operation – it’s an entire medical ecosystem.

Every procedure begins with an ultra-precise examination using the MS-39 tomograph.

  • Precision: The device creates a corneal map with micron resolution, combining topography with OCT technology.
  • Safety Signal: Data is automatically exported to the Schwind Atos laser. This eliminates the need for manual parameter entry by staff, completely ruling out the risk of error when transcribing diopter values or astigmatism axis.

As you lie under the laser, the system takes a picture of your eye and compares it with the iris pattern from the qualification examination. This iris registration allows the laser to recognize your eye and automatically compensate for its rotation in the supine position (known as cyclotorsion). This is critical for ideal astigmatism correction.

Most patients ask about laser speed. However, in modern ophthalmology, centration is the key factor determining vision quality.

In these procedures, the surgeon must center the laser before the device touches the eye. However, at the moment the laser is suctioned to the cornea (vacuum application), the eye may shift minimally (known as de-centration).

The Schwind Atos laser allows the surgeon to make a final, digital centration correction after the eye has been immobilized.

  1. The eye is already securely immobilized by vacuum.
  2. The Centrax software displays the patient’s ideal visual axis.
  3. The surgeon positions the treatment profile precisely at this point.

Even a millimeter shift can cause night glare (halos), blurred vision (ghosting), or reduced contrast. SmartSight Nova minimizes these risks through mathematical accuracy.

Feature / MethodSMILE (Older)SMILE ProCLEARSmartSight NOVA
Laser PlatformVisuMax 500VisuMax 800FEMTO Z8Schwind Atos (Nova)
Diagnostic IntegrationNone / ManualAverageAverageFull (MS-39)
Centration MomentBefore vacuumBefore vacuumBefore vacuumAFTER vacuum application
Iris RegistrationNoYesYesYes (Fully automatic)
Method PhilosophyProvenSpeedFlexibilityMaximum Precision
Surface SmoothnessStandardHighHighUltra-smooth (Low Energy)

Am I a Candidate?

SwissLaser Traffic Light System

Green Light
(Ideal Candidates)

Myopia up to -10D, astigmatism up to 5D. You are professionally active, drive at night, and want maximum protection against dry eye syndrome.

Yellow Light
(Consultation Required):

Very thin cornea or strong predisposition to dry eyes. We will use MS-39 diagnostics to check if Nova is safer for you than other methods.

Red Light
(Not Qualified – but alternatives exist):

Active keratoconus, advanced glaucoma, cataracts. In such cases, Swisslaser will propose an alternative (e.g., ICL phakic lenses).

Patients in Poland – especially in dynamic centers like Warsaw or Krakow – are looking for solutions that allow them to return quickly to office work and sports, without worrying about the stability of the results.

Dr. Victor Derhartunian (FEBO, FWCRS) explains:

“In my clinics in Warsaw and Krakow, I observe that patients value technological sovereignty. I chose the Schwind Atos system and SmartSight Nova because it gives me, as a surgeon, control that is lacking in other systems. We are not competing to make the procedure 3 seconds shorter. We are competing to ensure the laser hits the ideal optical point. The fact that we can correct centration after eye immobilization relieves pressure on the patient and gives me mathematical certainty of success.”

Czy Atos jest wolniejszy od SMILE Pro?

The laser beam’s operation itself in Atos is about 5-8 seconds longer. This difference is medically insignificant, while the gain in centration precision (Centrax system) is crucial for vision quality.

Dlaczego Nova jest lepsza do widzenia w nocy?

Thanks to precise centration on the visual axis and the “Low Energy” concept (low pulse energy), the cornea is smoother after the procedure, which drastically reduces light scattering after dark.

Czym jest ,,cyfrowy uścisk dłoni”?

This is our safety standard: data from the diagnostic device flows directly to the laser. This eliminates human error when entering vision defect parameters.

Jak szybko wrócę do pracy w biurze?

Most patients in Warsaw and Krakow return to work at a computer screen within 24-48 hours after the procedure.

Czy metoda Nova boli?

No. Thanks to local anesthetic eye drops and very low laser energy, the procedure is painless and highly comfortable.

Do not leave your vision to chance.
Experience the confidence that Swiss precision and the most advanced centration technology in Poland provide. Schedule a comprehensive MS-39 tomograph diagnostic at Swisslaser and find out if SmartSight Nova is your path to a life without limitations.